Type 5 Steam Chemical Integrator

Type 5 Chemical Integrators are the indicators which give proximate result to the biological indicator and they operate in direct proportion to biological death. This product that is used in a package during steam sterilization process consists of the chemical mixture which is on the part of the acceptance area if the sterilization is successful and on the part of reject area if the sterilization fails. There is no reference color in integrators, and the results can be interpreted according to the mixture migrating through the window.

<span class="ts-tooltip button-tooltip" data-title="Add to compare">Compare</span>
SKU:Product Code: 4AC5IN

TECHNICAL DATA SHEET

TYPE 5 STEAM CHEMICAL INTEGRATOR

PRODUCT CODE RELATED  STANDARDS

INTENDED USE

:     4AC5INT

:     4A Medical Steam Integrator is classified as Type 5 according to ISO 11140-1 standard.

:     4A Medical Steam Integrator are cycle verification indicators that confirm the presence or absence of specific time and temperature and saturated steam parameters during a cycle. The products allows the end user to identify incorrect packaging, load problems and sterilization failures.

OPERATION CONDITIONS :

4A Medical Steam Integrators are designed operate at steam cycle 121°C and 134ºC operation conditions. When the Integrator is placed in a sterilizer together with the load and sterilization conditions are met the ink is changing from solid into a liquid which is slowly absorbed by a strip over time. If accepted point is passed then sterilization is successful if it doesn’t pass accepted point then sterilization is not successful.

TERILIZATION  RESUTS

PRODUCT SPECIFICATIONS : The indicator is temperature, time and saturated steam concentration sensitive.

STORAGE AND DISPOSAL : The expired products are not used. It’s kept in the places with room temperature

without humidity and sun lights. It shouldn’t be in contact with liquid. Damaged and defective products are not used. Shelf life is 4 years after prodcution date.

PACKAGINGPacking contains 250 pieces of integrator. There is 20 pack in one cardboard

Product NameQTYSize
Type 5 Steam Chemical Integrator1x250 pcs

Reviews

There are no reviews yet.

Write a review

Your email address will not be published. Required fields are marked *

Bestsellers

Product Code: 4APBI

Plasma Biological Indicator

(0 Reviews)
  • Data Sheet
  • 4APBI
Biological indicators are test systems containing viable microorganisms providing a defined resistance to a specific sterilization process. A biological indicator provides information on whether necessary conditions were met to kill a specified number of microorganisms for a given sterilization process, providing a level of confidence in the process. Plasma Biological Indicator (4APBI) is specifically designed for the monitoring of Hydrogen Peroxide sterilization processes. The final readout should be made after 24hours of incubation at 60+/- 2 °C.
Product Code: 4ADXR03

Self Sealed Pouch

(0 Reviews)
  • Data Sheet
Self Sealing Pouches can be sealed with their self-adhesive feature on the closing part of pouch without need of sealer. Medical Paper provides maximum safety. Excellent adhesive resistant to over-exposure of steam. Superior barrier and quality with 60gsm or 70gsm medical kraft paper. Steam, EO and Formaldehyde (FO) indicators are water based and non-toxic.Strong seal-strength, visible sealing lines.Clean fibre-free opening. All materials comply with international standards.Opening direction marked.Conformity with EN 868-5.Apart from those standard sizes, as long as the width is one of the standards, there is no limit at lengths. Self Sealing Pouches are packed as 100 pieces wrapped in film according to requested dimension.
Product Code: 4AWTG

Washer Test (Glass)

(0 Reviews)
  • Data Sheet
  • 4AWTG
Product Code: 4ALG

Label Gun

(0 Reviews)
    • Data Sheet
 
Product Code: 4AEOBI

EO Biological Indicator

(0 Reviews)
  • Data Sheet
  • 4AEOBI
Biological indicators are test systems containing viable microorganisms providing a defined resistance to a specific sterilization process. A biological indicator provides information on whether necessary conditions were met to kill a specified number of microorganisms for a given sterilization process, providing a level of confidence in the process. 4A Ethylene Oxide Biological Indicator (4AEOBI) is specifically designed for the monitoring of ethylene oxide (EO) sterilization processes. The final readout should be made after 48 hours of incubation at 37+/- 2 °C.
Product Code: 4ADXR16

Sterilization Flat Pouches

(0 Reviews)
  • Data Sheet
Medical Paper provides maximum safety. Pouches constructed from high grade medical kraft paper and multilayer transparent co-polymer film. Strong seal strength.Superior barrier and quality with 60gsm or 70gsm medical kraft paper.Indicators which are water based , non toxic and give accurate result for steam, EO Gas and Formaldehyde (FO) Strong seal-strength, visible sealing lines.Clean fibre-free opening. All materials comply with international standards.Opening direction marked. Conformity with EN 868-5.Apart from those standard sizes, as long as the width is one of the standards, there is no limit at lengths. Sterilization Flat Pouches are packed as 100 pieces wrapped in film according to requested dimension.
Product Code: 4ADXR13

Bowie Dick Test Pack

(0 Reviews)
  • Data Sheet
Bowie Dick Test Packs are the testing packages that should be used before starting daily machine sterilization process for steam sterilization devices. Bowie Dick Test Pack is used for the purpose of testing whether there is air leakage and efficient steam penetration in the steam sterilizers. Bowie Dick Test Packs color change allows assurance of whether the steam sterilizers are ready for the sterilization or not. Different kinds of Bowie Dick Test Packs are available These are Bowie Dick Test Pack 200 (wrapped in medical paper, wrapped in crepe paper and BD in box), Bowie Dick Test Pack 400 (wrapped in medical paper and wrapped in crepe paper) and Bowie Dick Test Pack EWS (Early